ConfigMgr 2012 / SCCM 2012 Task Sequence fails with BCD error

ConfigMgr 2012 / SCCM 2012 Task Sequence fails with BCD error

Issue: OSD Task Sequence fails to be deployed via network booting. Issue occurs on all devices (different makes and models)

This error appears on screen

Your PC needs to be repaired

File: \Boot\BCD
Status : 0xc0000098
Info : The Windows Boot configuration data file does not contain a valid OS Entry.

OR




I resolved this by disabling and then re-enabling PXE support on the Distribution Point



Go to the Properties of the DP and uncheck the box "Enable PXE support for clients"

Wait for a short time while Windows Deployment Services uninstalls

Reboot the DP

Re-enable PXE support and wait while WDS re-installs

WDS usually requires a reboot so you should reboot again



Verify that the RemoteInstall folders have been populated

This is a safe process and has no effect on Config Mgr system files or packages


No comments:

Post a Comment